Table 2 Scan-rescan reproducibility in 5 multiple sclerosis patients and 5 healthy controls who underwent pre- and post-contrast susceptibility-weighted imaging scan one week apart.

From: Decreased brain venous vasculature visibility on susceptibility-weighted imaging venography in patients with multiple sclerosis is related to chronic cerebrospinal venous insufficiency

 

Pre-contrast SWI

ICC

Post-contrast SWI

ICC

ATVV for all vein sizes

0.891

< .001

0.912

< .001

   ATVV with diameter < .3 mm

0.812

.002

0.825

.001

   ATVV with diameter < .3-.6 mm

0.888

< .001

0.907

< .001

   ATVV with diameter < .6-9 mm

0.923

< .001

0.941

< .001

   ATVV with diameter > .9 mm

0.935

< .001

0.942

< .001

Venous intracranial fraction

0.791

.002

0.815

.001

Average distance from vein

0.738

.003

0.777

.002

  1. ATVV - apparent total venous volume; mm - millimeters