Table 7 Sensitivity, specificity and AUC’s (ROC analysis) of our proposed PTA scale and existing PTA scales

From: Development and external validation of a new PTA assessment scale

PTA Scale

1stAdministration

one hour after 1stadministration

24 hours after 1stadministration

 

 Sens. 

 Spec. 

 AUC 

 95% C.I. 

 Sens. 

 Spec. 

 AUC 

 95% C.I. 

 Sens. 

 Spec. 

 AUC 

 95% C.I. 

New PTA scale

68

77

0.77

0.69 - 0.85

76

91

0.85

0.73 - 0.97

80

95

0.89

0.81 - 0.97

GOAT

22

100

0.71

0.63 - 0.80

10

100

0.76

0.61 - 0.91

11

100

0.75

0.63 - 0.86

MOPTAS

92

43

0.84

0.77 - 0.90

67

91

0.78

0.64 - 0.93

85

100

0.92

0.86 - 0.99

WPTAS

89

43

0.80

0.73 - 0.87

57

91

0.75

0.60 - 0.90

83

100

0.91

0.84 - 0.98

R-WPTAS

46

97

0.72

0.64 - 0.80

38

96

0.66

0.50 - 0.83

50

100

0.74

0.63 - 0.86

  1. AUC, area under the curve; ROC, receiver operating characteristic; PTA, post-traumatic amnesia; Sens., Sensitivity,%; Spec., Specificity,%. Based on optimal scores. C.I., confidence interval. GOAT, Galveston orientation and amnesia test; MOPTAS, modified Oxford PTA scale; (R-)WPTAS, Revised-Westmead PTA scale.