Skip to main content

Table 2 Distribution of the subjects according to the results, and diagnostic utility of the Eurotest fordementia

From: Diagnostic accuracy of the Eurotest for dementia: a naturalistic, multicenter phase II study

Eurotest score

Patients with dementia

Patients with no dementia

Sensitivity

Specificity

LR+

LR-

16

76

28

0.75

0.93

10.71

0.27

17

4

10

0.79

0.90

7.90

0.23

18

3

7

0.82

0.88

6.83

0.20

19

3

8

0.85

0.86

6.07

0.17

20

6

17

0.91

0.82

5.06

0.11

21

2

18

0.93

0.77

4.04

0.09

22

2

9

0.95

0.75

3.80

0.07

23

5

283

0.95

0.70

3.17

0.07

Total

101

380

    
  1. LR, likelihood ratio