Skip to main content

Table 3 Reperfusion results and time-metrics

From: Stent-retriever assisted vacuum-locked extraction (SAVE) versus a direct aspiration first pass technique (ADAPT) for acute stroke: data from the real-world

Endpoint Overall ADAPT SAVE p Value
mTICI≥2b 86.0% 75.0% 93.5% 0.006
 Carotid T 80.0% 65.4% 93.1% 0.100
 M1 segment 90.4% 83.3% 94.8% 0.187
 M2 segment 81,8% 70.0% 91.7% 1
mTICI≥2c 45.6% 33.3% 54.5% 0.052
 Carotid T 36.4% 15.4% 55.2% 0.025
 M1 segment 55.3% 50% 58.6% 1
 M2 segment 27.3% 20.0% 33.3% 1
mTICI3 25.7% 22.2% 28.3% 1
 Carotid T 16.4% 11.5% 20.7% 1
 M1 segment 33.0% 32.8% 33.3% 1
 M2 segment 18.2% 10% 25% 1
Groin to reperfusion (Mean, SD) 55.2 ± 29.2 55.6 ± 31.3 52.1 ± 25.3 0.432
 Carotid T 66.9 ± 29.7 73.7 ± 32.9 61.1 ± 25.9 0.129
 M1 segment 46.5 ± 24.1 44.6 ± 25.8 47.7 ± 23.2 0.559
 M2 segment 50.8 ± 27.6 49.4 ± 26.2 51.8 ± 29.6 0.856
  1. mTICI modified thrombolysis in cerebral infarction score, SD standard deviation