Table 3 The effect of single sensor in detecting FOG

From: Recognition of freezing of gait in Parkinson’s disease based on combined wearable sensors

Sensor

Sensitivity (Recall)

Specificity

Accuracy

precision

F-score

Left/right thigh accelerometer

74.04%

71.90%

90.39%

89.27%

88.97%

87.76%

42.29%

38.95%

53.83%

50.53%

Left/right shank accelerometer

73.06%

71.58%

89.86%

89.15%

88.40%

87.62%

40.68%

38.62%

52.26%

50.17%

Left/right thigh gyroscope

72.08%

73.51%

89.88%

88.73%

88.33%

87.41%

40.45%

38.25%

51.82%

50.32%

Left/right shank gyroscope

71.99%

72.39%

88.95%

88.82%

87.47%

87.39%

38.38%

38.17%

50.07%

49.98%

Waist accelerometer

71.73%

——

88.85%

——

87.35%

——

38.19%

——

49.84%

——

Left/right foot gyroscope

71.26%

69.51%

88.21%

88.70%

86.73%

87.03%

36.64%

36.96%

48.40%

48.26%

Waist gyroscope

70.05%

——

88.46%

——

86.86%

——

36.62%

——

48.10%

——

Left/right sole pressure sensor

69.07%

68.83%

88.23%

87.96%

86.56%

86.29%

35.91%

35.35%

47.25%

46.71%

Left/right foot accelerometer

68.68%

68.15%

81.52%

88.24%

80.40%

86.49%

26.21%

35.61%

37.94%

46.78%