Skip to main content

Table 4 Objective balance and gait outcome measures collected at home with both virtual instrumented L-shape mobility test and daily-life mobility monitoring (7 days), divided by balance domains

From: Balance telerehabilitation and wearable technology for people with Parkinson’s disease (TelePD trial)

Balance and Gait Domains/Measures

Virtual instrumented L-shape mobility test, 3 wearable sensors

Daily-life mobility with passive monitoring, 3 wearable sensors

Postural Sway

 Root Mean Square, Mediolateral

X

No

 Root Mean Square, AnteroPosterior

X

No

 Jerk, Mediolateral

X

No

Anticipatory Postural Adjustment (APAs)

 Peak Mediolateral

X

No

 First Step Range of Motion

X

No

 Gait: average

 Gait speed

X

X

 Angle at Heel Strike

X

X

 Stride length

X

X

Turning: Average

 Duration

X

X

 Velocity

X

X

 Angle

X

X

 # Steps

X

X

Gait Variability

 Gait Speed

No

X

 Angle at Heel Strike

No

X

 Stride length

No

X

 Swing Time

No

X

 Duration

No

X

 Velocity

No

X

 Angle

No

X

 # Steps

No

X