Skip to main content

Parent artery reconstruction for large or giant cerebral aneurysms using a Tubridge flow diverter (PARAT): study protocol for a multicenter, randomized, controlled clinical trial

Abstract

Background

The treatment of large (10-25 mm) or giant (≥25 mm) cerebral aneurysms remains technically challenging, with a much higher complication and recanalization rate than that is observed for smaller aneurysms. The use of a flow diverter seems to facilitate the treatment of this special entity. In a previous single-center prospective study approved by the Ethics Committee and China Food and Drug Administration (CFDA), we obtained promising results, showing remarkable safety and effectiveness for the Tubridge flow diverter. Nevertheless, the previous study may have been limited by biases due to its single-center design and limited number of subjects. Furthermore, although various articles have reported durable results from treating aneurysms using flow diverters, increasing questions have arisen about this form of treatment. Thus, prospective, multiple-center, randomized trials containing more subjects are needed.

Methods/Design

This study is a multicenter, randomized, controlled clinical trial comparing clinical outcomes for patients with unruptured large/giant intracranial aneurysms treated with either conventional stent-assisted coiling or flow diverter implantation. A total of 124 patients who fulfill the inclusion and exclusion criteria will be randomized into either a treatment group or a control group in the ratio of 1:1. The treatment group will receive Tubridge implantation alone or combined with bared coils, and the control group will be treated with stent-assisted coiling (bare coils). The primary endpoint will be the complete occlusion rate at 6-month follow-up. Secondary endpoints include the immediate technique success rate, overall mortality, adverse events (ischemic stroke or intracranial bleeding) within 30 days, 90 days and 1 year post-operation, and the rate of intra-stent stenosis and thrombosis 6 months post-operation.

Discussion

This prospective trial may provide more information on the safety and efficacy of the Tubridge flow diverter and may potentially change the strategy for treatment of large or giant aneurysms.

Trial registration

The trial is registered on the Chinese Clinical Trial Registry: ChiCTR-TRC-13003127

Peer Review reports

Background

Intracranial aneurysms are pathological bulges of cerebral arteries caused by various etiologies, such as inflammation or hemodynamic stress. Their rupture often results in a catastrophic outcome, and they are associated with high rates of mortality and morbidity [1]. Large (10-25 mm) or giant (≥25 mm) aneurysms are a subtype of intracranial aneurysm with a much higher rupture risk and poorer outcomes compared with small aneurysms [2, 3]. Despite technical advances, the treatment of large or giant aneurysms remains technically challenging, with a much higher complication and/or recanalization rate [48].

In recent years, with better understanding of the occurrence and development of intracranial aneurysms, the concept of vessel reconstruction, especially flow diversion, has attracted the interest of neurointerventionalists worldwide. Accordingly, various flow diversion devices have emerged around the world; the best known devices include the Pipeline (ev3, Irvine, CA, USA) and the Silk (Balt Extrusion, Montmorency, France), which gained the approval of the FDA and the CE and have been used clinically in over 50 countries [916].

Compared with conventional endovascular treatment such as stent-assisted coiling, the Flow Diverter (FD) can alter the blood flow, reduce the hemodynamic stress in the aneurysm neck, and promote intra-saccular thrombus formation [1720]. A series of studies have shown that flow diverters can significantly improve the outcome of intracranial aneurysms [911, 13, 14, 16].

The Tubridge is a new type of flow diversion device developed by MicroPort Medical Company (Shanghai, China) based on our previous clinical experience of multiple stenting in intracranial aneurysms and the hemodynamic study of intracranial aneurysms. Referring to its structure, the Tubridge FD is actually a braided, self-expanding “stent-like” device with flared ends. Currently, Tubridge FDs are available in many diameters (2.5-6.5 mm) and lengths (12–45 mm). A large Tubridge (diameter ≥3.5 mm) is braided with 62 nickel- titanium microfilaments and 2 platinum-iridium radiopaque microfilaments, whereas a smaller Tubridge (diameter <3.5 mm) is composed of 46 nitinol and 2 platinum-iridium microfilaments. All Tubridge FDs were designed with a pore size of 0.040-0.050 mm2 at a nominal diameter, aiming to provide a high metal coverage (approximately 30.0%-35.0%) at the aneurysmal neck after full opening. In addition to its use of a nickel-titanium alloy (commonly known as nitinol, which has the advantages of shape-holding memory and super-elasticity) and flared ends, the Tubridge FD offers some structural improvements compared with the Pipeline and the Silk. The use of platinum-iridium material for the radiopaque microfilaments allows for improved visualization of both diameter and length during the procedure. More importantly, the design, which includes more braided microfilaments for large-size FDs, decreases the shortening rate of the FD after its full opening.

In a previous single-center prospective study approved by the Ethics Committee and China Food and Drug Administration (CFDA), we obtained promising results, showing remarkable safety and effectiveness for the Tubridge FD. In that study(data in press), a total of 33 Tubridge FDs were successfully implanted for 28 large or giant aneurysms, with the exception of one mid-stent with a poor opening, resulting in a technical success rate of 97.0% (32/33). Follow-up angiographies, taken at a mean follow-up of 9.9 m (5–24 m), were available for 25 aneurysms. Of those, 18 (72.0%) aneurysms were completely occluded, 6 (24.0%) were improved, and 1 (4.0%) was unchanged. All visible covered branches and the parent artery were patent, with no stenosis or obliteration. During a follow-up period of 6 to 30 months (mean 19.0 months), the symptoms experienced were resolved in 13 patients, improved in 6, and showed no change in 4. No procedure-related morbidity or mortality occurred. Nevertheless, biases may exist in the study due to its single-center design and limited number of subjects. Prospective, multiple-center, randomized trials that include more subjects are needed.

Furthermore, although various articles have reported durable results from treating aneurysms with FDs, increasing questions have arisen about this type of treatment. For example, is the occurrence of peri-procedure intra-parenchymal hemorrhage accidental or related to the application of the device? Are ischemic complications encountered more often with FDs than with conventional therapy [2125]? These questions need to be answered through prospective trials, which have been lacking to date.

Based on these considerations, we initiated this trial with the aim of evaluating the safety and effectiveness of the Tubridge FD for unruptured large or giant aneurysms (≥10 mm).

Methods

Objectives

The aim of the trial is to assess the safety and effectiveness of the Tubridge flow diverter in the treatment of unruptured large or giant intracranial saccular aneurysms.

Study design

This study is a multicenter, randomized, controlled clinical trial comparing clinical outcomes for patients with unruptured large/giant intracranial aneurysms treated with either conventional stent-assisted coiling or with flow diverter implantation. The study will be conducted in 13 centers, each of which have performed more than 30 stent-assisted coiling procedures per year in the past 5 years, after gaining approval from local ethics committees. A total of 124 patients who fulfill the inclusion and exclusion criteria will be randomized into either a treatment group or a control group in the ratio of 1:1. The treatment group will receive Tubridge FD implantation alone or combined with bare coils, and the control group will receive stent-assisted coiling (bare coils). Procedure-related complications, adverse events, and follow-up data will be collected prospectively to evaluate the safety and effectiveness of the Tubridge FDs.

Hypothesis

Compared with conventional stent-assisted coiling, Tubridge FD implantation does not enhance the risk of procedure-related complications and may lead to a higher complete occlusion rate and a decreased recanalization rate.

Primary and secondary outcomes

The primary endpoint will be the complete occlusion rate at 6-month follow-up.

Secondary endpoints will include:

  1. 1.

    Immediate technique success rate.

  2. 2.

    Overall morbidity or mortality (assessment time point: 30 days, 90 days and 1 year post-operation).

  3. 3.

    Ischemic stroke or intracranial bleeding (assessment time point: 30 days, 90 days and 1 year post-operation)

  4. 4.

    The rate of intra-stent stenosis (assessment time point: 6 months post-operation)

  5. 5.

    The rate of intra-stent thrombosis (assessment time point: 6 months post-operation)

  6. 6.

    General adverse events (assessment time point: 30 days, 90 days and 1 year post-operation).

Participants

Inclusion criteria

Patients eligible for inclusion will meet the following criteria:

  1. 1.

    Age 18 years to 75 years, male or nonpregnant female.

  2. 2.

    Unruptured internal carotid artery or vertebral artery saccular aneurysm (including recanalized aneurysms), confirmed by CTA, MRA, or DSA.

  3. 3.

    Width of aneurysm neck ≥4 mm, and aneurysm size ≥10 mm.

  4. 4.

    Parent vessel with a diameter range of 2.0-6.5 mm.

  5. 5.

    Indications for Enterprise stent-assisted coiling and Tubridge FD implantation with or without coiling.

  6. 6.

    Is willing to return to the investigational site for follow-up according to our protocol.

  7. 7.

    Understands the nature of the procedure and provision of written informed consent.

Exclusion criteria

Patients will be excluded if they meet any of the following criteria:

  1. 1.

    No appropriate route to access the aneurysm via endovascular approach.

  2. 2.

    A non-treated arteriovenous malformation (AVM) in the territory of the target aneurysm.

  3. 3.

    Ruptured aneurysms.

  4. 4.

    Anatomy not appropriate for endovascular treatment due to severe intracranial vessel tortuosity or stenosis, or intracranial vasospasm not responsive to medical therapy.

  5. 5.

    Major surgery within the previous 30 days or planned within the next 90 days after the enrollment date.

  6. 6.

    Severe neurological deficit that renders the patient incapable of living independently (modified Rankin score ≥4).

  7. 7.

    Co-morbid conditions that may limit survival to less than one year.

  8. 8.

    Enrollment in another trial.

  9. 9.

    Poor compliance (inability to complete the full study).

  10. 10.

    Allergy or contraindication for the use of nickel-titanium alloy.

  11. 11.

    Inability to receive anti-platelet or anticoagulant medication.

  12. 12.

    History of life-threatening allergy to contrast dye.

Withdrawal criteria

Patients who have been included in this trial and have given written informed consent but are not able to complete the whole study for any reason will be withdrawn, including circumstances as below:

  1. 1.

    The subjects voluntarily quit the trial for various reasons.

  2. 2.

    Occurrence of serious adverse events. The subjects, main researchers, ethics committee, supervisor or CFDA terminate the research based on the consideration of ethics.

  3. 3.

    Early termination of the process based on the investigator’s judgment (to prevent development of severe complications, and so on).

  4. 4.

    Significant deviation in implementation, or the subject failed to comply with the protocol.

  5. 5.

    Lost of follow-up due to changes in working/living places, or fortuitous accident. When these fortuitous accidents occurs, including traffic accident, death,or bone fracture, et al., Close follow-up should be conducted to determine their relationship with the usage of Tubridge FD.

  6. 6.

    flawed or absence of informed consents.

When the subjects are withdrawn, the researcher would try their best to contact the subjects via telephone call, letter, clinic interview, et al., and document the reasons why they are withdrawn in detail; of which, those experienced adverse effects must be recorded in the CRF if the adverse effects were thought related to the devices used in this trial. All raw data of those enrolled and treated subjects must be kept including subjects withdrawn.

Method of allocation and randomization

All recruited subjects will be randomly allocated to either the flow diverter implantation group or the control group using a web-based platform linked to a central randomization database. According to existing research, aneurysms larger than 15 mm with posterior circulation are thought to carry a higher complication rate [26, 27]. Stratification will be performed for aneurysm size (15 mm versus >15 mm) and aneurysm location (anterior circulation versus posterior circulation).

Sample size

The sample size calculation is based on the study of Mocco et al. [28], who reported the midterm results of 219 patients treated with Enterprise-assisted stent coiling. In their research, the 6-month complete occlusion rate was 40%; of these, 46.4% were cases of aneurisms smaller than 7 mm. Because the aneurysmal complete occlusion rate decreases with aneurysm size, we assume the 6-month complete occlusion rate to be 35% following Enterprise stent-assisted coiling for aneurysms larger than 10 mm. Furthermore, the 6-month complete occlusion rate for the Tubridge FD implantation is predicted to be 65% according to our previous results and to those of other studies using Silk or Pipeline implantation. Thus, at least 98 patients will need to be randomized in the ratio of 1:1 (49 in each group) to obtain a positive result (two-tailed test, significance level of α = 0.05, power (1 - β) = 0.80). Considering a withdrawn-patient maximum of 20%, the sample size will increase to at least 124 (62 in each group).

Procedure

For all recruited patients, dual antiplatelet drugs (300 mg/day aspirin plus 75 mg/day clopidogrel) will be given for at least 3 days before the procedure. All procedures will be performed under general anesthesia and via the transfemoral approach. After sheath placement, heparin will be given to maintain the activated clotting time at 2 to 3 times the baseline throughout the procedure. Next, a proper (7 F) guiding catheter will be placed in the distal internal carotid artery or vertebral artery. Subsequently, the aneurysms will be treated with conventional stent-assisted coiling or FD implantation with or without coiling. All detailed data, such as the aneurysm’s actual size, width of the aneurysmal neck, aneurysmal shape, diameter of the parent artery, and treatment results, will be recorded. The post-operative antiplatelet regimen will be administered as follows: <6 w: 300 mg aspirin + 75 mg clopidogrel; 6 w-3 m: 100 mg aspirin + 75 mg clopidogrel; ≥3 m: 100 mg aspirin indefinitely.

Planned patient follow-up

Arrangements will be made for all patients to be evaluated at discharge and 30 d (±7 d), 90 d (±15 d), and 1 year (±30 d) post-treatment, either by clinic or telephone contact. Postoperative DSA follow-up is required after 6 m (±30 d).

Safety and efficacy assessment

During the procedure and at each follow-up time point, information about the patients will be documented in detail. All data will be collected and analyzed by an independent central laboratory to compare the complication rate, morbidity, mortality, as well as initial and follow-up angiographic results between the two groups. If any adverse event has occurred, the detailed symptoms, duration, severity, possible reasons, actions taken, results and other relevant information will be reported. In addition, researchers must fill out a serious adverse event (SAE) form and notify the principal investigator, institutional review board (IRB), China Food and Drug Administration (CFDA), Clinical Research Associate (CRA), and other regulatory authorities within 24 hours.

Immediate angiographic results will be classified according to Raymond’s classification for those treated with stent-assisted coiling or FD implantation combined with coils [29]. For aneurysms treated with the Tubridge FD alone, flow modifications will be defined as disrupted inflow jet, slow flow (if the contrast circulation within the aneurysm is slowed), or reduced contrast filling (if increased contrast stagnation is observed within the aneurysm at the late venous phase of the angiographic series) [30].

The angiographic results will be classified into four categories when compared with the immediate degree of embolization: 1) Occluded, defined as no contrast filling into the aneurysm sac; 2) Improved, defined as decreased contrast filling into the aneurysm sac; 3) Stable, defined as unchanged contrast filling into the aneurysm sac; 4) Recanalized, defined as increased contrast filling into the aneurysm sac. The intra-stent stenosis will also be documented.

Table 1 shows a summary of the intervention and follow up.

Table 1 Summary of measurement items and point of data capture

Planned analyses

Statistical analyses will be conducted based on an intention-to-treat (ITT) population. Participants who are recruited and treated will be considered the full analysis set (FAS), those who complete treatment and the entire follow-up protocol will be considered the per-protocol set (PPS), and those who are treated and have at least one safety evaluation will be considered the safety set (SS). Last observation carried forward (LOCF) method will be implemented to handle the missing data from withdrawn subjects, who would be included in FAS.

Comparisons of demographic information will first be conducted to measure the balance between the two groups. Then evaluation of primary and secondary outcome will conducted as below:

Primary outcomes:

The comparison of the treatment groups with regard to the primary endpoint will be performed with the data of the Full Analysis Set as well as of the Per Protocol Set. In case the two analyses will lead to different conclusions the result of the analysis of the Per Protocol Set is deciding.

Use superiority test for analysis of primary outcome. The formal test problem is as follows:

Test problem for the complete occlusion rate at 6-month follow-up:

Let πT be the rate of complete occlusion rate of treatment group at 6-month follow-up.

Let πc be the rate of complete occlusion rate of control group at 6-month follow-up.

The superiority margin δ is 0.

Test problem:

H0: πT -πc ≥ 0

H1: πT -πc < 0

α = 0.05 (2-sided)

The alternative hypothesis will not be accepted unless the lower limit of the 95% confidence interval of the difference of occlusion rate lies above the superiority margin.

Secondary outcomes:

Immediate occlusion rate will be conducted in FAS group, while other safety evaluation will be be conducted in SS group. For quantitative data, t-test (for equal variances and normal distribution) or Wilcoxon rank sum test could be applied according to the distribution of the data. The categorical variables will be compared between study arms using Chi-square tests or Fisher's exact tests (if Chi-square test is not valid). Besides, for immediate technique success rate, 95% confidence interval of each groups and difference between groups will be estimated.

The statistical analysis process will be conducted by a statistician at the Institute of Clinical Evaluation affiliated with Beijing University, and the data will be analyzed using Statistical Analysis System (SAS) software version 9.2 (SAS Institute Inc., Cary, NC, USA).

Ethics approval

Thirteen institutes will take part in this trial, and the trial has been approved by all relevant local ethics boards including Shanghai changhai hospital ethics committee, Huashan hospital ethics committee, Xuanwu hospital ethics committee, Tiantan hospital ethics committee, ethics committee of the second affiliated hospital of Zhejiang university, Henan People’s hospital ethics committee, ethics committee of the first affiliated hospital of the third military medical college of PLA, ethics committee of the first affiliated hospital of China Medical University, ethics committee of General Hospital of Shenyang military Region, Renji hospital ethics committee, ethics committee of the second affiliated hospital of Guangzhou medical college, ethics committee of General Hospital of Guangzhou military Region. Written informed consent will be obtained from each participant prior to enrollment. The trial is registered on the Chinese Clinical Trial Registry: ChiCTR-TRC-13003127.

Monitor and supervise of the trial

The whole process of the trial will be supervised by a Trial Steering Committee and a data and safety monitoring committee. The Trial Steering Committee consists of 3 independent members, they will guide and supervise the trial from the beginning, and provide expert advice to the investigators on all aspects of the trial, including decisions about continuation or termination of the trial or amendments to the protocol.

The data and safety monitoring committee consists of 2 biostatisticians, 2 professor expertise in the treatment of intracranial aneurysms, and an independent company. They will work together to make sure that monitor and supervise the whole process of the trial to ensure that 1)the trial is being conducted in accordance with the principles of Good Clinical Practice and the relevant regulations of China. 2) any adverse events during the study are promptly reported to the sponsor, the Clinical Trials Units, and related agency. 3) any variances from the clinical trial program to the sponsor. 4) the devices are used as suggested by the protocol. 5) all subjects are fully informed, and informed consent are achieved. 6) the clinical report forms are promptly and clearly completed. And they will review the progress of the trial and accruing trial data, including updated figures on recruitment, data quality and safety data, and provide expert advice to the investigators on all aspects of the trial, including decisions about continuation or termination of the trial or amendments to the protocol.

Discussion

Large and giant aneurysms carry the risk of a significantly worse outcome compared with small aneurysms [3]. The ISUIA study showed that the risks of rupture within 6 years for large and giant aneurysms are as high as 13% and 27%, respectively [2]. The treatment of this entity, whether with conventional endovascular treatment or surgery, imposes a great challenge for both neurosurgeons and neurointerventionalists. A deconstructive approach such as internal carotid artery(ICA) occlusion requires sufficient compensation from other vessels; even so, rates of ischemia as high as 4%-15% have been recorded [7]. In addition, there are also concerns about de novo aneurysm following ICA occlusion [31]. Bypass surgery, especially high-flow bypass, preceding ICA occlusion may help reduce ischemic complications, but operative complications are not uncommon, though reports in different manuscripts vary [32]. In contrast, reconstructive approaches such as stent-assisted coiling aiming to preserve the parent artery are associated with much higher recanalization rates, ranging from 19.2% to 50%. However, the use of FDs, including Pipeline, Silk, and Tubridge, have recently shown excellent and promising results [914, 16]. Because of this, we began this prospective trial, which may provide more information on the safety and efficacy of the Tubridge flow diverter and may change the treatment strategy for large or giant aneurysms if the hypotheses are confirmed.

A similar trial, MARCO POLO, which was designed to compare the results of coiling (with balloon remodeling and/or stents when necessary) to those of Silk FD implantation, is being conducted in 7 countries around the world [33]. However, there are apparent differences between our trial and MARCO POLO, such as the target aneurysms and the different active comparators used.

Although sporadic studies have reported FD application in ruptured intracranial aneurysms, basilar trunk aneurysms, and aneurysms beyond the circle of Willis, its safety is not confirmed yet [3437]. Anti-platelet therapy may enhance the aneurysm rupture risk. Furthermore, ischemic events may also be encountered more often when FDs are implanted at the basilar trunk or in parent arteries beyond the circle of Willis due to the involvement of small perforators. To ensure the maximum safety of all subjects and to obtain results more efficiently, we restricted our target to unruptured Internal carotid artery or vertebral artery aneurysms.

The Enterprise is a type of intracranial self-expansion stent with a closed-cell design. It is one of the most widely used stents in clinics around the world [28, 38, 39], and sufficient data has also demonstrated its safety. In this trial, therefore, we choose to use Enterprise-assisted coiling in the comparative arm of the study to evaluate the safety and efficacy of the Tubridge FD.

Trial status

The trial was initiated in October 2012 and is currently open for recruitment.

References

  1. Feigin VL, Lawes CM, Bennett DA, Barker-Collo SL, Parag V: Worldwide stroke incidence and early case fatality reported in 56 population-based studies: a systematic review. Lancet Neurol. 2009, 8: 355-369. 10.1016/S1474-4422(09)70025-0.

    Article  PubMed  Google Scholar 

  2. Unruptured intracranial aneurysms--risk of rupture and risks of surgical intervention: International Study of Unruptured Intracranial Aneurysms Investigators. N Engl J Med. 1998, 339: 1725-1733.

    Article  Google Scholar 

  3. Barrow DL, Alleyne C: Natural history of giant intracranial aneurysms and indications for intervention. Clin Neurosurg. 1995, 42: 214-244.

    CAS  PubMed  Google Scholar 

  4. Kars HZ, Gurelik M: Clipping of large and giant aneurysms of anterior circulation. Turk Neurosurg. 2011, 21: 53-58.

    PubMed  Google Scholar 

  5. Darsaut TE, Darsaut NM, Chang SD, Silverberg GD, Shuer LM, Tian L, Dodd RL, Do HM, Marks MP, Steinberg GK: Predictors of clinical and angiographic outcome after surgical or endovascular therapy of very large and giant intracranial aneurysms. Neurosurgery. 2011, 68: 903-915.

    PubMed  Google Scholar 

  6. Hauck EF, Wohlfeld B, Welch BG, White JA, Samson D: Clipping of very large or giant unruptured intracranial aneurysms in the anterior circulation: an outcome study. J Neurosurg. 2008, 109: 1012-1018. 10.3171/JNS.2008.109.12.1012.

    Article  PubMed  Google Scholar 

  7. Gonzalez NR, Duckwiler G, Jahan R, Murayama Y, Vinuela F: Challenges in the endovascular treatment of giant intracranial aneurysms. Neurosurgery. 2006, 59: S113-124. discussion

    Article  PubMed  Google Scholar 

  8. Sluzewski M, Menovsky T, Van Rooij WJ, Wijnalda D: Coiling of very large or giant cerebral aneurysms: long-term clinical and serial angiographic results. AJNR Am J Neuroradiol. 2003, 24: 257-262.

    PubMed  Google Scholar 

  9. Becske T, Kallmes DF, Saatci I, McDougall CG, Szikora I, Lanzino G, Moran CJ, Woo HH, Lopes DK, Berez AL, et al: Pipeline for Uncoilable or Failed Aneurysms: Results from a Multicenter Clinical Trial. Radiology. 2013, 267: 858-868. 10.1148/radiol.13120099.

    Article  PubMed  Google Scholar 

  10. Yeung TW, Lai V, Lau HY, Poon WL, Tan CB, Wong YC: Long-term outcome of endovascular reconstruction with the Pipeline embolization device in the management of unruptured dissecting aneurysms of the intracranial vertebral artery. J Neurosurg. 2012, 116: 882-887. 10.3171/2011.12.JNS111514.

    Article  PubMed  Google Scholar 

  11. O'Kelly CJ, Spears J, Chow M, Wong J, Boulton M, Weill A, Willinsky RA, Kelly M, Marotta TR: Canadian Experience with the Pipeline Embolization Device for Repair of Unruptured Intracranial Aneurysms. AJNR Am J Neuroradiol. 2013, 34: 381-387. 10.3174/ajnr.A3224.

    Article  PubMed  Google Scholar 

  12. McAuliffe W, Wycoco V, Rice H, Phatouros C, Singh TJ, Wenderoth J: Immediate and midterm results following treatment of unruptured intracranial aneurysms with the pipeline embolization device. AJNR Am J Neuroradiol. 2012, 33: 164-170. 10.3174/ajnr.A2727.

    Article  CAS  PubMed  Google Scholar 

  13. Wagner A, Cortsen M, Hauerberg J, Romner B, Wagner MP: Treatment of intracranial aneurysms. Reconstruction of the parent artery with flow-diverting (Silk) stent. Neuroradiology. 2012, 54: 709-718. 10.1007/s00234-011-0949-9.

    Article  PubMed  Google Scholar 

  14. Velioglu M, Kizilkilic O, Selcuk H, Kocak B, Tureci E, Islak C, Kocer N: Early and midterm results of complex cerebral aneurysms treated with Silk stent. Neuroradiology. 2012, 54: 1355-1365. 10.1007/s00234-012-1051-7.

    Article  PubMed  Google Scholar 

  15. Tahtinen OI, Manninen HI, Vanninen RL, Seppanen J, Niskakangas T, Rinne J, Keski-Nisula L: The silk flow-diverting stent in the endovascular treatment of complex intracranial aneurysms: technical aspects and midterm results in 24 consecutive patients. Neurosurgery. 2012, 70: 617-623. 10.1227/NEU.0b013e31823387d4.

    Article  PubMed  Google Scholar 

  16. Leonardi M, Cirillo L, Toni F, Dall'olio M, Princiotta C, Stafa A, Simonetti L, Agati R: Treatment of intracranial aneurysms using flow-diverting silk stents (BALT): a single centre experience. Interv Neuroradiol. 2011, 17: 306-315.

    CAS  PubMed  PubMed Central  Google Scholar 

  17. Trager AL, Sadasivan C, Seong J, Lieber BB: Correlation between angiographic and particle image velocimetry quantifications of flow diverters in an in vitro model of elastase-induced rabbit aneurysms. J Biomech Eng. 2009, 131: 034506-10.1115/1.3049528.

    Article  PubMed  PubMed Central  Google Scholar 

  18. Sadasivan C, Cesar L, Seong J, Wakhloo AK, Lieber BB: Treatment of rabbit elastase-induced aneurysm models by flow diverters: development of quantifiable indexes of device performance using digital subtraction angiography. IEEE Trans Med Imaging. 2009, 28: 1117-1125.

    Article  PubMed  PubMed Central  Google Scholar 

  19. Augsburger L, Farhat M, Reymond P, Fonck E, Kulcsar Z, Stergiopulos N, Rufenacht DA: Effect of flow diverter porosity on intraaneurysmal blood flow. Klin Neuroradiol. 2009, 19: 204-214. 10.1007/s00062-009-9005-0.

    Article  PubMed  Google Scholar 

  20. Huang QH, Yang PF, Zhang X, Shi Y, Shao XM, Liu JM: [Effects of flow diverter with low porosity on cerebral aneurysms: a numerical stimulative study]. Zhonghua Yi Xue Za Zhi. 2010, 90: 1024-1027.

    PubMed  Google Scholar 

  21. Cruz JP, Chow M, O'Kelly C, Marotta B, Spears J, Montanera W, Fiorella D, Marotta T: Delayed ipsilateral parenchymal hemorrhage following flow diversion for the treatment of anterior circulation aneurysms. AJNR Am J Neuroradiol. 2012, 33: 603-608. 10.3174/ajnr.A3065.

    Article  CAS  PubMed  Google Scholar 

  22. Berge J, Tourdias T, Moreau JF, Barreau X, Dousset V: Perianeurysmal brain inflammation after flow-diversion treatment. AJNR Am J Neuroradiol. 2011, 32: 1930-1934. 10.3174/ajnr.A2710.

    Article  CAS  PubMed  Google Scholar 

  23. Turowski B, Macht S, Kulcsar Z, Hanggi D, Stummer W: Early fatal hemorrhage after endovascular cerebral aneurysm treatment with a flow diverter (SILK-Stent): Do we need to rethink our concepts?. Neuroradiology. 2011, 53: 37-41. 10.1007/s00234-010-0676-7.

    Article  PubMed  Google Scholar 

  24. Van Rooij WJ, Sluzewski M: Perforator infarction after placement of a pipeline flow-diverting stent for an unruptured A1 aneurysm. AJNR Am J Neuroradiol. 2010, 31: E43-44. 10.3174/ajnr.A2034.

    Article  CAS  PubMed  Google Scholar 

  25. Kulcsar Z, Houdart E, Bonafe A, Parker G, Millar J, Goddard AJ, Renowden S, Gal G, Turowski B, Mitchell K, et al: Intra-Aneurysmal Thrombosis as a Possible Cause of Delayed Aneurysm Rupture after Flow-Diversion Treatment. AJNR Am J Neuroradiol. 2011, 32: 20-25.

    Article  CAS  PubMed  Google Scholar 

  26. Maimon S, Gonen L, Nossek E, Strauss I, Levite R, Ram Z: Treatment of intra-cranial aneurysms with the SILK flow diverter: 2 years' experience with 28 patients at a single center. Acta Neurochir (Wien). 2012, 154: 979-987. 10.1007/s00701-012-1316-2.

    Article  Google Scholar 

  27. Molyneux A, Kerr R, Stratton I, Sandercock P, Clarke M, Shrimpton J, Holman R: International Subarachnoid Aneurysm Trial (ISAT) of neurosurgical clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms: a randomised trial. Lancet. 2002, 360: 1267-1274. 10.1016/S0140-6736(02)11314-6.

    Article  PubMed  Google Scholar 

  28. Mocco J, Fargen KM, Albuquerque FC, Bendok BR, Boulos AS, Carpenter JS, Fiorella DJ, Hoh BL, Howington JU, Liebman KM, et al: Delayed thrombosis or stenosis following enterprise-assisted stent-coiling: is it safe? Midterm results of the interstate collaboration of enterprise stent coiling. Neurosurgery. 2011, 69: 908-913. 10.1227/NEU.0b013e318228490c.

    Article  CAS  PubMed  Google Scholar 

  29. Raymond J, Guilbert F, Weill A, Georganos SA, Juravsky L, Lambert A, Lamoureux J, Chagnon M, Roy D: Long-term angiographic recurrences after selective endovascular treatment of aneurysms with detachable coils. Stroke. 2003, 34: 1398-1403. 10.1161/01.STR.0000073841.88563.E9.

    Article  PubMed  Google Scholar 

  30. Lubicz B, Collignon L, Raphaeli G, De Witte O: Pipeline flow-diverter stent for endovascular treatment of intracranial aneurysms: preliminary experience in 20 patients with 27 aneurysms. World Neurosurg. 2011, 76: 114-119. 10.1016/j.wneu.2011.02.015.

    Article  PubMed  Google Scholar 

  31. Zhou Y, Yang P, Zhang Y, Liu J: Posterior cerebral artery-posterior communicating artery (PCA-PComA) aneurysms: report of five cases and literature review. Neurol India. 2012, 60: 228-230. 10.4103/0028-3886.96409.

    Article  PubMed  Google Scholar 

  32. Van Doormaal TP, van der Zwan A, Verweij BH, Langer DJ, Tulleken CA: Treatment of giant and large internal carotid artery aneurysms with a high-flow replacement bypass using the excimer laser-assisted nonocclusive anastomosis technique. Neurosurgery. 2006, 59: ONS328-334.

    PubMed  Google Scholar 

  33. Efficacy Trial of Intracranial Aneurysm Treatment Using Two Different Endovascular Techniques(Marco Polo). 2014, http://www.clinicaltrials.gov/ct2/show/NCT01084681?term=Marco+Polo&rank=1,

  34. Pistocchi S, Blanc R, Bartolini B, Piotin M: Flow diverters at and beyond the level of the circle of willis for the treatment of intracranial aneurysms. Stroke. 2012, 43: 1032-1038. 10.1161/STROKEAHA.111.636019.

    Article  PubMed  Google Scholar 

  35. Causin F, Pascarella R, Pavesi G, Marasco R, Zambon G, Battaglia R, Munari M: Acute endovascular treatment (<48 hours) of uncoilable ruptured aneurysms at non-branching sites using silk flow-diverting devices. Interv Neuroradiol. 2011, 17: 357-364.

    CAS  PubMed  PubMed Central  Google Scholar 

  36. Siddiqui AH, Abla AA, Kan P, Dumont TM, Jahshan S, Britz GW, Hopkins LN, Levy EI: Panacea or problem: flow diverters in the treatment of symptomatic large or giant fusiform vertebrobasilar aneurysms. J Neurosurg. 2012, 116: 1258-1266. 10.3171/2012.2.JNS111942.

    Article  PubMed  Google Scholar 

  37. Kulcsar Z, Ernemann U, Wetzel SG, Bock A, Goericke S, Panagiotopoulos V, Forsting M, Ruefenacht DA, Wanke I: High-profile flow diverter (silk) implantation in the basilar artery: efficacy in the treatment of aneurysms and the role of the perforators. Stroke. 2010, 41: 1690-1696. 10.1161/STROKEAHA.110.580308.

    Article  PubMed  Google Scholar 

  38. Jia J, Lv X, Liu A, Wu Z, Li Y: Enterprise stent-assisted coiling of wide-necked intracranial aneurysms: clinical and angiographic follow-up. Interv Neuroradiol. 2012, 18: 426-431.

    CAS  PubMed  PubMed Central  Google Scholar 

  39. Fargen KM, Hoh BL, Welch BG, Pride GL, Lanzino G, Boulos AS, Carpenter JS, Rai A, Veznedaroglu E, Ringer A, et al: Long-term results of enterprise stent-assisted coiling of cerebral aneurysms. Neurosurgery. 2012, 71: 239-244. 10.1227/NEU.0b013e3182571953.

    Article  PubMed  Google Scholar 

Pre-publication history

Download references

Acknowledgements

This work was supported by subject of National Science and Technology Supporting Program (2011BAI08B14), and project of Shanghai Science and Technology Commission (11DZ1921603).

Author information

Authors and Affiliations

Authors

Corresponding authors

Correspondence to Qing-Hai Huang or Jian-Min Liu.

Additional information

Competing interests

During the development, Prof. Liu had given some advice about the design of this device, and offered some data about our previous hemodynamic studies. The other authors declare they have no competing interests.

Authors’ contributions

QHH and JML conceived of the study. YX, BH, WYZ, and YBF designed the study. PFY and YZ contributed to the draft of the manuscript. QL and RZ contributed to the revision of the manuscript. All authors read and approved the final manuscript.

Yu Zhou, Peng-Fei Yang contributed equally to this work.

Rights and permissions

Open Access  This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made.

The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder.

To view a copy of this licence, visit https://creativecommons.org/licenses/by/4.0/.

The Creative Commons Public Domain Dedication waiver (https://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Zhou, Y., Yang, PF., Fang, YB. et al. Parent artery reconstruction for large or giant cerebral aneurysms using a Tubridge flow diverter (PARAT): study protocol for a multicenter, randomized, controlled clinical trial. BMC Neurol 14, 97 (2014). https://doi.org/10.1186/1471-2377-14-97

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/1471-2377-14-97

Keywords