- Research article
- Open access
- Published:
Scepter dual‐lumen balloon catheter for Onyx embolization for dural arteriovenous fistula
BMC Neurology volume 21, Article number: 31 (2021)
Abstract
Background
This study aimed to evaluate the efficacy and safety of Scepter dual-lumen balloon catheter for transarterial Onyx embolization of dural arteriovenous fistula (DAVF).
Methods
Transarterial Onyx embolization using a Scepter dual-lumen balloon catheter (Scepter-assisted Onyx embolization) for DAVF was attempted in a total of 35 patients (mean age, 52.5 years; M:F = 24:11) between October 2012 and December 2018. The results of Scepter-assisted Onyx embolization were evaluated with respect to total procedural and Onyx injection times, the types and number of feeders requiring embolization, angiographic and clinical outcomes, and treatment-related complications.
Results
Initial presentations were non-hemorrhagic neurological deficits in 10, intracranial hemorrhage in 8, seizure in 7, headache in 7, and intractable tinnitus in 3. All DAVF were aggressive type (Borden type 2, 14.3 %; type 3, 85.7 %). Scepter-assisted Onyx embolization resulted in immediately complete occlusion in 33 patients (94.3 %) and near complete occlusion in 2 patients. Middle meningeal artery (51.4 %) was the most commonly used for Scepter-assisted technique, followed by occipital artery (42.9 %), ascending pharyngeal artery (2.9 %) and superficial temporal artery (2.9 %). There was no difference in complete occlusion rate between middle meningeal artery and the other arteries (94.4 % versus 94.1 %). The median number of total feeders embolized was 1 (range, 1–3). The median total procedural time was 45 minutes (range, 21 minutes – 127 minutes) and the median Onyx injection time was 11 minutes (range, 3 minutes – 25 minutes). All patients recovered completely (n = 31) or partially (n = 4) from presenting symptoms. Treatment-related complications occurred in 2 patients, of whom one had a permanent morbidity (2.8 %, ipsilateral facial nerve palsy). No patient showed a recurrence on follow-up imaging (median, 15 months; range, 3–56 months).
Conclusions
Scepter-assisted transarterial Onyx embolization showed a very high complete occlusion rate with a low morbidity and no recurrence in aggressive type DAVF. Scepter dual-lumen balloon catheter seems to be a useful tool for transarterial Onyx embolization of DAVF.
Background
Multi-therapeutic options such as stereotactic radiosurgery, microsurgery and endovascular treatment are used for treatment of DAVF [1, 2]. The Onyx Liquid Embolic agent (eV3 Endovascular, Plymouth, Minnesota) facilitates controlled penetration into the fistula, thereby improving the cure rate of endovascular mean. Therefore, Onyx has been a popular agent for AVF and AVM. Effective penetration requires an antegrade flow of Onyx from the feeding artery to the fistula site. With conventional microcatheter-based techniques, an initial proximal plug is often necessary, unless the tip of a microcatheter could be positioned completely wedged at the target feeding artery. That is also true with a detachable microcatheter. Subsequently, conventional technique takes a considerable amount of time to form a firm plug in order to facilitate effective penetration and to avoid reflux of Onyx. Recently, several small case series have documented that use of a dual-lumen balloon catheter (Scepter, Microvention, Tustin, California) enables more effective penetration and requires shorter injection time than the conventional microcatheter technique [3, 4].
The objective of this study was to evaluate the efficacy and safety of Scepter dual-lumen balloon catheter for transarterial Onyx embolization of dAVF.
Methods
The Institutional Review Boards at all participating hospitals involved approved this retrospective study and waived the patient informed consent for study inclusion. Written informed consent for embolization was obtained from the patient or a legal representative before treatment.
All patients in whom the Scepter dual-lumen balloon catheter was attempted as a primary delivery tool for Onyx embolization for aggressive-type DAVF were identified from a prospectively maintained neurointerventional database in 3 hospitals between October 2012 and December 2018. Aggressive-type was defined as DAVF with cortical reflux (Borden type 2) or a directly draining cortical vein (Borden type 3).
Transarterial Onyx embolization
All procedures were performed under general anesthesia. If it had been one of the feeders of DAVF, middle meningeal artery was preferentially selected for Onyx embolization. For overcoming the difficulty, if any, in navigation of the Scepter balloon catheter, the following techniques were used. (1) The tip of scepter balloon catheter was almost always steam-shaped for improving navigability. (2) The distal access catheter has always been used combined with a Shuttle 6F sheath for more supporting the Scepter balloon catheter. (3) If needed, exchange technique was employed for placing the scepter balloon catheter into the target point of the feeding artery using a microcatheter with inner lumen of 0.0165-inch and a 300-cm length, 0.014-inch exchangeable microwire (Transend, Stryker). In detail of exchange technique, a 0.0165-inch microcatheter was navigated to the target point of the feeding artery. An exchangeable wire was placed followed and the microcatheter was removed. Finally, Scepter balloon catheter was advanced over the exchange wire. In addition, vasodilator (Nimodipine, 0.3–0.5 mg) was infused into the feeding artery before the navigation of Scepter catheter to prevent vasospasm. The essential prerequisite of the target position of the Scepter balloon catheter within the feeding artery is that there is no functioning arterial branch arising between the point and the fistula.
Main Outcomes
We evaluated the results of Scepter-assisted transarterial Onyx embolization with respect to treatment-related complications, angiographic outcome, total procedural time, Onyx injection time, and number of feeders needed for completion of embolization. Angiographic outcomes were classified as complete occlusion, near complete occlusion, or incomplete occlusion. Complete occlusion of d-DAVF was defined as no visualization of the isolated sinus or shunted cortical vein in the delayed venous phase on the completion angiogram. Near complete occlusion was defined as delayed visualization of the isolated sinus or shunted vein on the venous phase, with marked stasis of contrast material (≥ 2 seconds). Incomplete occlusion was defined as visualization of the isolated sinus or shunted vein on the arterial phase of the completion angiogram, with stasis of contrast material < 2 seconds.
Routine follow-up imaging was scheduled at 6 months with magnetic resonance angiography (MRA) or digital subtraction angiogram (DSA) and 24 months after the embolization. MRA was used for first follow-up modality in 20 cases and DSA was in 15 cases. MRA was routinely used for second follow-up, unless patient’s presenting symptoms were not improved or aggravated. If MRA source images show any high signal on the lesion in cases that MRA was used for follow-up modality, or patient’s presenting symptoms were not improved or aggravated, DSA was performed for confirmation. Angiographic and follow-up imaging outcomes were assessed by 2 independent raters who did not participated in the treatment. Inter-rater agreements were almost perfect for both immediate and follow results (kappa value = 0.97 and 0.93, respectively).
Statistical analysis
Since this study evaluated the efficacy and safety of Scepter balloon catheter as a primary tool for Onyx embolization of DAVF without comparison with the other tools or methods, only descriptive statistics are presented. All data are presented as a mean and range for continuous variables and as a number and percentage for categorical variables.
Results
Of the 53 patients who underwent transarterial embolization for cranial dAVF between September 2012 and December 2018. The Scepter balloon catheter was attempted to navigate to the target point (distal to the origin of potentially dangerous branch) of the feeding artery in 36 patients. Of them, the navigation of Scepter balloon catheter failed in 1 patient and Scepter balloon catheter was used as a primary delivery tool for Onyx delivery for DAVF in a total of 35 patients (97.2 %; mean age, 52.5 years; M:F = 24:11). Baseline clinical and angiographic characteristics of the patients are summarized in Table 1. Initial presentations were non-hemorrhagic neurological deficits in 10, intracranial hemorrhage in 8, seizure in 7, headache in 7, and intractable tinnitus in 3. All DAVF were aggressive type; Borden type 2, 5 (14.3 %) and type 3, 30 (85.7 %), respectively.
Procedural details, clinical and angiographic outcomes are summarized in Table 2.
Scepter-assisted Onyx embolization resulted in immediately complete occlusion in 33 patients and near complete occlusion in 2 patients. Exchange technique was applied with a 0.014-inch thickness and 300-cm length wire (Transcend exchangeable wire, Stryker or Grandslam, Abbort, ) for navigation of Scepter dual-lumen balloon catheter to a target position in a very tortuous feeder artery in 5 patients (14.3 %).(Fig. 1) Planned adjunctive embolization with N-butyl cyanoacrylate was conducted in 2 patients (5.7 %) with multiple feeders immediately before Scepter-assisted Onyx embolization.(Fig. 2) The median number of total feeders embolized was 1 (range, 1–3). Middle meningeal artery (51.4 %) was the most commonly used for Scepter-assisted technique, followed by occipital artery (42.9 %), ascending pharyngeal artery (2.9 %) and superficial temporal artery (2.9 %). There was no difference in complete occlusion rate between middle meningeal artery and the other arteries (94.4 % versus 94.1 %). The median total procedural time was 45 minutes (range, 21 minutes – 127 minutes) minutes and the median Onyx injection time was 11 minutes (range, 3 minutes – 25 minutes). Comparing the Onyx injection time between middle meningeal artery and occipital artery, it was significantly shorter at the middle meningeal artery (9 ± 4 minutes) than at the occipital artery (13 ± 9 minutes). (Table 2) All patients recovered completely (n = 31) or partially (n = 4) from presenting symptoms. Treatment-related complications occurred in 2 patients, of whom one had a permanent morbidity (2.8 %, ipsilateral facial nerve palsy). One patient presented with intractable right facial spasm due to neurovascular compression from the engorged draining vein of the dAVF at right superior petrosal sinus. The patient experienced right facial palsy after Onyx embolization, likely due to penetration of Onyx into the petrous branch, which supplies the petrous segment of the facial nerve via artery-to-artery anastomosis. The other patient experienced a transient contralateral sensory change but completely recovered in a week.
No patient showed a recurrence on follow-up imaging (median, 15 months; range, 3 months – 56 months).
Discussion
The results of this study demonstrated that (1) the navigation of Scepter balloon catheter to the target point (distal to the potentially dangerous branch) of the feeding artery was successful in 97.2 % of the attempted cases, (2) Scepter-assisted transarterial Onyx embolization showed a very high successful (94.3 % complete and 5.7 % near complete) occlusion rate with a low permanent morbidity (2.8 %), (3) Scepter-assisted technique was as effective using the other feeding arteries as middle meningeal artery, and finally, (4) the Onyx injection (median, 11 minutes; range, 3–37 minutes) and total procedural (median 35 minutes; range, 21–127 minutes) times were quite shorter than those of conventional technique in the literature, onyx injection time ranged 30minutes from 15 to 60 minutes [5]. Since Scepter dual lumen balloon microcatheter was introduced [3], several small case series showed that it might be a promising Onyx delivery tool for the treatment of dural AVF. In this study, we evaluated that Scepter balloon catheter can be used as a primary tool for Onyx embolization, to our best knowledge, in the largest population.
Traditionally, transarterial embolization of dAVF has been associated with a high failure rate and was considered palliative or adjunctive to transvenous embolization. In the last 10 years, however, there has been a paradigm shift toward transarterial embolization of dAVF. Since its introduction, Onyx has gained widespread popularity as a primary embolic agent for various vascular lesions. Due to its cohesive property, Onyx can allow for a more controlled injection and penetration into the target lesion. As a result, contemporary series have consistently demonstrated cure rates with transarterial embolization exceeding 70 % [6]. Nevertheless, to control the direction of the Onyx toward the target lesion with conventional technique, the formation of a proximal plug around the microcatheter tip should be preceded before antegrade propagation of Onyx in most cases. This, in turn, results in increased procedural and fluoroscopy times. Furthermore, excessive and unwanted reflux of Onyx into proximal segment of the feeding artery may not rarely occur, which leads to incomplete occlusion or failure of embolization. Such a phenomenon is more common in highly resistant and tortuous artery such as occipital artery than middle meningeal artery. Therefore, most investigators recommend middle meningeal artery as a primary conduit for Onyx delivery [7,8,9].
Recently, Kim et al. reported a small case series that compared the results of conventional microcatheter technique (n = 14) and Scepter-assisted technique (n = 16). That study demonstrated that utilization of Scepter-assisted technique clearly increased the immediate complete occlusion rate (86.7 % versus 35.7 %) and decreased total procedural time (62 ± 32 minutes versus 171 ± 88 minutes), Onyx injection time (10 ± 6 minutes versus 49 ± 32 minutes, and number of feeding arteries (1 versus 2) required for completion of embolization. The results of the present study also showed similar results to those of Scepter-assisted technique group, which can provide additional evidence to the usefulness of Scepter-assisted technique.
When recommending Scepter balloon catheter as a primary delivery tool for Onyx embolization, the navigability of the balloon catheter into the target feeding artery is a major huddle. In this study, for navigation of the Scepter balloon catheter to a very tortuous feeding artery, exchange technique was used in 14.3 % and distal access catheter in addition to shuttle sheath has been routinely used since its introduction. Subsequently, the navigation of Scepter balloon catheter was attempted in approximately two thirds of all cranial dAVF and was successful in all but one. In fact, the navigation of the Scepter balloon catheter to the target point of the feeding artery succeeded in all cases after using a distal access catheter.
Middle meningeal artery is the most common feeding artery of cranial dAVF and recommended as a primary conduit for Onyx delivery in literature [7,8,9,10]. However, middle meningeal artery is not always the feeder artery of dAVF and furthermore often trivially contributes as a feeder. Occipital artery is a second most common contributing artery but has usually very tortuous course and high resistance because it is trans-osteal artery. Therefore, the cure rate of Onyx embolization with conventional technique is lower using occipital artery than middle meningeal artery. It has been suggested as a major cause of transarterial Onyx embolization failure with conventional technique [10]. In the present study, middle meningeal artery and occipital artery was selected for Scepter-assisted technique in 51.4 % and 42.9 %, respectively. However, there was no difference in complete occlusion rate between middle meningeal artery and the other arteries. It is largely because the firm inflated balloon of Scepter catheter makes it much easier to penetrate via a highly resistant occipital artery into the fistula. On the other hand, the Onyx injection time was shorter at the middle meningeal artery than at the occipital artery. It suggests that middle meningeal artery is better than occipital artery even for Scepter-assisted Onyx embolization in terms of the injection time if both arteries are usable.
The complication associated with onyx embolization include catheter entrapment, cranial nerve damage and distal propagation of onyx [11,12,13]. In meta-analysis of trans arterial onyx embolization for the intracranial dural fistulas, procedure-related morbidity was 3 % (95 % CI: 1 %, 5 %; I2, 0 %) [14]. In this study, treatment-related complications occurred in 2 patients, of whom one had a permanent morbidity (2.8 %, ipsilateral facial nerve palsy). There was no arterial rupture due to balloon over-inflation. All treated feeding arteries were external carotid artery branches which have external elastic lamina and thicker media, compared to intradural cerebral arteries in which external elastic lamina is absent. Therefore, the branches of external carotid artery may be quite endurable in the condition of stretching by balloon over-inflation. Even if dural arterial rupture happens, in our opinion, it can be easily controlled by further injection of onyx for embolization of the ruptured artery because any functioning branch do not arise from the target point of the artery. The final concern is entrapment of the balloon catheter. In our experience, however, although some distance of Onyx reflux occurred around the inflated balloon, deflation of the balloon easily separated the catheter from the Onyx coating vessel wall and retrieval of the Scepter catheter is very easy, taking less than 10 seconds in all cases.
Limitation
This study has several limitations inherent to retrospective analysis. This study did not compare Scepter-assisted technique with the other technique. However, the prevalence of dAVF requiring treatment is not so high in our country enough for randomized study. Furthermore, although all consecutive cases of Onyx embolization for dAVF were not treated by Scepter-assisted technique, it was already a frontline technique for transarterial Onyx embolization in our hospital because the preceding result of the technique had been very promising as previously reported [4]. Another limitation is that DSA was not used for the first follow-up imaging in all cases, which may miss a small slow-flow residual fistula. However, because the sensitivity of evaluating dAVF using MRA source image was very high [4, 15] and no patient showed recurrent symptom or recanalization on the follow-up after complete occlusion, the durability of Scepter-assisted technique may be reliable.
Conclusions
Scepter-assisted trans arterial Onyx embolization showed a very high complete occlusion rate with a low morbidity and no recurrence in aggressive type DAVF. Scepter dual-lumen balloon catheter seems to be useful tool for transarterial Onyx embolization of DAVF.
Availability of data and materials
The datasets used and analyzed during the current study are available from the corresponding author on reasonable request.
References
Kiyosue H, Hori Y, Okahara M, Tanoue S, Sagara Y, Matsumoto S, et al. Treatment of intracranial dural arteriovenous fistulas: current strategies based on location and hemodynamics, and alternative techniques of transcatheter embolization. Radiographics. 2004;24:1637–53.
Starke RM, McCarthy DJ, Chen CJ, Kano H, McShane B, Lee J, et al. Evaluation of stereotactic radiosurgery for cerebral dural arteriovenous fistulas in a multicenter international consortium. J Neurosurg. 2019;1:1–8.
Jagadeesan BD, Grigoryan M, Hassan AE, Grande AW, Tummala RP. Endovascular balloon-assisted embolization of intracranial and cervical arteriovenous malformations using dual-lumen coaxial balloon microcatheters and Onyx: initial experience. Neurosurgery. 2013;73:238–43.
Kim JW, Kim BM, Park KY, Kim DJ, Kim DI. Onyx Embolization for Isolated Type Dural Arteriovenous Fistula Using a Dual-Lumen Balloon Catheter. Neurosurgery. 2016;78:627–36.
Abud TG, Nguyen A, Saint-Maurice JP, Abud DG, Bresson D, Chiumarulo L, et al. The Use of Onyx in Different Types of Intracranial Dural Arteriovenous Fistula. AJNR. 2011;32:2185–91.
Oh SH, Choi JH, Kim BS, Lee KS, Shin YS: Treatment Outcomes according to Various Treatment Modalities for Intracranial Dural Arteriovenous Fistulas in the Onyx Era: a 10-year Single Center Experience. World Neurosurg. 2019;126:825-34.
Deng J-P, Li J, Zhang T, Yu J, Zhao Z-W, Gao G-D. Embolization of dural arteriovenous fistula of the anterior cranial fossa through the middle meningeal artery with Onyx. Clin Neurol Neurosurg. 2014;117:1–5.
Fox B, Elijovich L, VanLandingham M, Hoit D, Arthur AS. Endovascular Treatment of Intracranial Dural Arteriovenous Fistulas. Neurosurgery. 2014;74:42–9.
Santillan A, Nanaszko M, Burkhardt J-K, Patsalides A, Gobin YP, Riina HA. Endovascular management of intracranial dural arteriovenous fistulas: A review. Clin Neurol Neurosurg. 2013;115:241–51.
Hu YC, Newman CB, Dashti SR, Albuquerque FC, McDougall CG. Cranial dural arteriovenous fistula: transarterial Onyx embolization experience and technical nuances. Journal of NeuroInterventional Surgery. 2011;3:5.
Ertl L, Bruckmann H, Kunz M, Crispin A, Fesl G. Endovascular therapy of low- and intermediate-grade intracranial lateral dural arteriovenous fistulas: a detailed analysis of primary success rates, complication rates, and long-term follow-up of different technical approaches. J Neurosurg. 2017;126:360–7.
Gaynor BG, Elhammady MS, Jethanamest D, Angeli SI, Aziz-Sultan MA. Incidence of cranial nerve palsy after preoperative embolization of glomus jugulare tumors using Onyx. J Neurosurg. 2014;120:377–81.
Qureshi AI, Mian N, Siddiqi H, Qureshi MH, Malik AM, Rauf Afzal M, et al. Occurrence and Management Strategies for Catheter Entrapment with Onyx Liquid Embolization. J Vasc Interv Neurol. 2015;8:37–41.
Sadeh-Gonike U, Magand N, Armoiry X, Riva R, Labeyrie PE, Lamy B, et al. Transarterial Onyx Embolization of Intracranial Dural Fistulas: A Prospective Cohort, Systematic Review, and Meta-Analysis. Neurosurgery. 2018;82:854–63.
Hirai T, Korogi Y, Ikushima I, Shigematsu Y, Morishita S, Yamashita Y. Usefulness of source images from three-dimensional time-of-flight MR angiography after treatment of cavernous dural arteriovenous fistulas. Radiat Med. 2003;21:205–9.
Acknowledgements
No specific to declare.
Funding
No funding was received for this study.
Author information
Authors and Affiliations
Contributions
Substantial contribution to the conception or design of the work: BMK. Acquisition, analysis, or interpretation of the data for the work: CKJ, KYP, DJK, JWL, JhC and JHK. Drafting the work or revising it critically for important intellectual concept: CKJ and BMK. Final approval of the version to be published: CKJ, BMK, JWL,DJK, JhC and JHK. Agree to be accountable for all aspects of the work in ensuring that questions related to the accuracy or integrity of any part of the work are appropriately investigated and resolved: CKJ, BMK, JWL, DJK, JhC, and JHK. The author(s) read and approved the final manuscript.
Corresponding author
Ethics declarations
Ethics approval and consent to participate
The data analysis and this study were approved by the Institutional Research Ethics Committee of the Severance hospital in Yonsei university (3-2019-0203). All procedures performed in the studies involving human participants were in accordance with the ethical standards of our Institutional Review Board with the 1964 Helsinki Declaration and its later amendments or comparable ethical standards. In this retrospective study, the requirement for informed consent was waived.
Consent for publication
Not applicable.
Competing interests
The authors declare that they have no conflict of interest.
Additional information
Publisher’s Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
About this article
Cite this article
Jang, C.K., Kim, B.M., Park, K.Y. et al. Scepter dual‐lumen balloon catheter for Onyx embolization for dural arteriovenous fistula. BMC Neurol 21, 31 (2021). https://doi.org/10.1186/s12883-021-02046-6
Received:
Accepted:
Published:
DOI: https://doi.org/10.1186/s12883-021-02046-6